AUTOMATION SYSTEMS

PRODUCT SELECTOR

SMART IN FLOW CONTROL

5578-E

Heating and district heating controller

USAGE

  • Building automation

APPLICATION

  • Meter data recording
  • Heating control
  • Domestic hot water
  • District heating
  • Local heat supply
  • Cooling control
  • Solar thermal systems
  • Temperature control

Special features

  • Heating and district heating controller
  • SAM DIGITAL READY
  • The TROVIS 5578-E Heating and District Heating Controller is used to control max. three control circuits:
    • Control of a primary heat exchanger or boiler with max. two mixing and one non-mixing heating circuit (both outdoor temperature controlled) as well as control of DHW heating in the secondary circuit
    • Outdoor-temperature-controlled buffer storage tank control with max. two mixing heating circuits and continuous-flow hot water module
    • Control of two outdoor-temperature-controlled heating circuits and a DHW heating with three valves in the primary circuit
    • Control of three outdoor-temperature-controlled heating circuits with three valves in the primary circuit
    • Extension to 6 control circuits with expansion module TROVIS I/O
    • Direct access to the operating modes and essential parameters of the individual control circuits using a rotary pushbutton
    • Enter and retrieve data intuitively by turning and pressing the button
    • LC display with plain-text and icons
    • 365-day clock with max. four time schedules (without TROVIS I/O) and automatic summer time/winter time changeover
    • Max. three times-of-use per day (entered in steps of 15 minutes)
    • Room panels can be connected for the individual heating circuits
    • Demand-driven control by set point demand by subsequent controllers using device bus or an 0 to 10 V signal
    • Applications including solar thermal DHW available
    • Instantaneous heating systems with water flow sensor configurable
    • Heating characteristic optionally based on gradient or four points
    • Flexible limitation of the return flow temperature
    • Adaptation: automatic adaptation of the heating characteristic (room temperature sensor required)
    • Optimization: calculation of the best possible activation and deactivation times for heating (room temperature sensor required)
    • Drying of jointless floors function with adjustable parameters
    • Controller flash EPROM (operating system) can be updated
    • Integrated meter bus interface for communication with max. three meter bus units
    • Galvanically isolated RS-485 interface for Modbus RTU/device bus communication
    • Ethernet interface for Modbus TCP/IP communication and connection to SAM DISTRICT ENERGY
    • Configuration and parameter setting with TROVIS-VIEW Software over Ethernet interface
    • Trend viewer
    • Alarm table
    • Time-stamped setting changes
    • Event list
    • Firmware installation guide: iOS / Android

Accessories

Options

  • - - -

Information

  • T 5578-E

    TROVIS 5578-E Heating and District Heating Controller
    [EN][DE]

Support

  • KA 5500-Z

    TROVIS I/O
    [EN][DE]
  • KA 5578-E

    TROVIS 5578-E Heating and District Heating Controller
    [EN][DE][FR]
  • EB 5578-E

    TROVIS 5578-E Heating and District Heating Controller
    With graphics display
    Firmware version 2.6x
    [EN][DE]
  • EB 5578-E

    Heizungs- und Fernheizungsregler TROVIS 5578-E
    mit Grafikdisplay
    Firmwareversion 2.5x
    [DE]
  • EB 5578-E

    Heizungs- und Fernheizungsregler TROVIS 5578-E
    mit Grafikdisplay
    Firmwareversion 3.00.xx
    [DE]

Software

  • Boot Manager
    Tool zur Installation von Firmware-Updates
    Tool for installing firmware updates
    Version 1.62
    [ZIP]
  • Wichtige Hinweise zur Aktualisierung der Firmware auf Ihrem Gerät
    Important information on updating the firmware on your device
    [PDF]
  • Erweiterungsmodul/Expansion module TROVIS I/O
    Firmware V1.2.0
    SAM Gateway Konfigurator als Tool zur Installation von Firmware-Updates notwendig
    SAM Gateway Configurator required as tool for installing firmware updates
    [ZIP]
  • Firmware V 3.00.xx
    Installationsguide: iOS / Android
    [B55]
  • SAM Gateway Configurator
    Tool zur Installation von Firmware-Updates
    Tool for installing firmware updates
    Version 2.4.2
    [ZIP]

Certificates

Only up-to-date documents are shown in the product selector. Check the documentation site for a list of all documents available.

Pin product

Pin items on your list and contact us if you have any product-related questions.

WATCHLIST

Wallet is empty
Back to product selector